• PCD1.M2110R1 (PCD1.Room)

  • Central processing units

Saia PCD1.Room (Saia PCD1.M2110R1) is a programmable room controller for sophisticated solutions with many communication options. In addition to the I/Os that are already integrated, the controller offers a free I/O slot for an individual expansion with inputs/outputs or communication options. Web/IT functions for mobile operation, for instance, are also already onboard. Furthermore, Saia PCD1.Room offers various possibilities for integrating other systems in the room through standard communication interfaces. (Energy) efficient and individual room automation can be easily implemented as a result. The controller also provides a good basis for achieving the energy efficiency classes according to EN 15232:2012.

Documentation

System Catalogue : PCD1

Extract 26-215_A0150 System Catalogue : PCD1

Chapter ChA015:
Automation Stations PCD1

ENG18 .pdf 2.75 MB Download
FRA18 .pdf 2.75 MB Download
GER18 .pdf 2.76 MB Download
ITA18 .pdf 2.75 MB Download

PCD1.M2110R1 (Room)

Manual 27-619 PCD1.M2110R1 (Room)

Hardware manual for room controller based on PCD1

ENG04 .pdf 12.40 MB Download
FRA04 .pdf 12.25 MB Download
GER04 .pdf 12.22 MB Download

IO-Modules

Manual 27-600 IO-Modules

I/O modules for the series PCD1 | PCD2 and PCD3

ENG10 .pdf 18.74 MB Download
FRA10 .pdf 17.08 MB Download
GER10 .pdf 19.21 MB Download
ITA10 .pdf 18.80 MB Download

Systemcable and adapter

Manual 26-792 Systemcable and adapter

ENG07 .pdf 2.05 MB Download
FRA07 .pdf 3.47 MB Download
GER07 .pdf 3.44 MB Download
ITA07 .pdf 3.46 MB Download

PCD2.F2xxx - serial interface modules

Manual 27-649 PCD2.F2xxx - serial interface modules

Physical interfaces for specific protocols

ENG02 .pdf 3.04 MB Download
FRA02 .pdf 3.03 MB Download
GER02 .pdf 2.93 MB Download
ITA02 .pdf 2.97 MB Download

TCP/IP - Ethernet for the Saia PCD® Serie

Manual 26-776 TCP/IP - Ethernet for the Saia PCD® Serie

ENG13 .pdf 21.09 MB Download
FRA13 .pdf 20.91 MB Download
GER13 .pdf 10.50 MB Download
IT03 Archive .pdf 4.43 MB Download

TCP/IP-Enhancements

Manual 26-867 TCP/IP-Enhancements

ENG05 .pdf 3.55 MB Download
FRA05 .pdf 3.47 MB Download
GER05 .pdf 3.51 MB Download

Leaflet: PCD1.M2110R1

Readme 35-004 Leaflet: PCD1.M2110R1

Saia PCD1.M2110R1 controller

ENG06 .pdf 0.12 MB Download

Drill hole pattern for PCD1.M2xx0

Tutorial 26-064 Drill hole pattern for PCD1.M2xx0

ENG01 .pdf 0.32 MB Download
FRA01 .pdf 0.30 MB Download
GER01 .pdf 0.30 MB Download
ITA01 .pdf 0.30 MB Download
SPA01 .pdf 0.30 MB Download

EPLAN product macros, DWG and DXF files can be found here.

Firmware used in production

The actual COSinus FW is available from the COSinus firmware page.

Good to know

  • PG5 2.1.100 or later is required for working with the PCD1.M2110R1.

  • Smart Rio Manager and Profibus RIO functions are not supported! 
  • Limitation of remote RIO's (a maximum of 10 S-Bus and 10 Modbus station units is allowed per PCD1.M2110R1).
  • On the slot 1, a PCD2.W525 module is already plugged on delivery. If this module is missing, the controller doesn’t go into RUN-mode!
  • With a PCD FW>1.22.25 a maximum of 10 selectable addresses are allowed. Check Opens external link in new windowFAQ
  • Information about PCD7.W600 on this link 

PCD1

  • How to know whether the circuit board of the PCD is fitted with a Swissbit micro-SD memory card? (FAQ #102070)
  • How to copy csv-Files and Webeditorproject files which are stored on the Intflash of a PCD, if you are replacing an internal micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102069)
  • What is stored on the micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102068)
  • How can the micro SD memory card on the circuit board of a PCD controller be replaced? (FAQ #102067)
  • On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052)
  • Are devices or software developed from Saia-Burgess Controls affected by the Domain Name System (DNS) vulnerabilities, published with the report name NAME:WRECK? (FAQ #102046)
  • Are devices or software developed from Saia-Burgess Controls affected by AMNESIA:33 or SUNBURST? (FAQ #102042)
  • Are SBC devices affected by the zero-day vulnerabilities ‘Ripple20’, related to the low-level TCP/IP software library developed by Treck, Inc.? (FAQ #102036)
  • Inputs of a W525 could be perturbed from an other input? (FAQ #102007)
  • No Refresh from State of I/O's from E-Line Rio- Moduls after Fbox Update (FAQ #102001)
  • How should I configure the triac output of an E-line PCD1.G360x-C15 (FAQ #101984)
  • Which FBox are supported by E-line? (FAQ #101967)
  • What are the maximum energy consumption values for Energy meters and Energy Managers/ E-controllers? (FAQ #101899)
  • Which Texts are writeable/editable during Runtime on a PCD? (FAQ #101801)
  • Lifetime expectancy of the Renata Lithium battery on recent PCD compared to previous PCD generations (FAQ #101780)
  • How to dump the memory of a PCD (with Saia PCD® COSinus firmware)? (FAQ #100833)
  • I forgot the password for my PCD/PCS! How can I access it again? (FAQ #100639)
  • Which extension memory chips are recommended / supported (FAQ #100507)
  • Is the XOB 5 "No response from I/O module (I/O Quit Failure)" supported by the PCD3? (FAQ #100501)
  • Why can't I connect a PCD over Ethernet after replacing its Ethernet module? (FAQ #100156)
  • Can input/output modules be changed under tension (hot-plug)? (FAQ #100111)

PCD1 / _Firmware Classic

  • It's possible to connect SBC PCD's directly to the internet? (FAQ #102060)
  • What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102058)
  • Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026)
  • PCD Firmware 1.28.16 or 1.24.69 fix the Ethernet frame padding information leakage (FAQ #102011)
  • What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102010)
  • Lon Bindings lost after power off / on with FW 1.26.15 (FAQ #101999)
  • What are the differences between the COSinus firmwares FW 1.24.67 and FW 1.26.31? (FAQ #101987)
  • What is the meaning of the PCD history entry ‘FWDnld UnknownFW’? (FAQ #101959)
  • How to find more information based on the error message "SF not loaded"? (FAQ #101568)
  • What does CSF stand for? (FAQ #101566)
  • Overview of the current production firmware versions (FAQ #101304)
  • How to implement a software watchdog (FAQ #101285)
  • Why do I sporadically get communication errors when connecting a PCD/PCS in "Secure S-Bus Data Mode"? (FAQ #101180)
  • Why do I get a "68k add Error" when writing a text on the S-Web Server? (FAQ #101049)
  • Why is the message: "Failed to get data on alarm.exe" displayed on the alarming page? (FAQ #100963)
  • Is it possible reading the PCD "IP address" from the user program? (FAQ #100952)
  • Register corruption on a PCD1.M1x5 due to bug in firmware booter (FAQ #100645)
  • Error LED of PCD is lit! How to find the problem? (FAQ #100269)
  • What EPROM burner is recommended to create firmware chips for PCD's? (FAQ #100256)
  • Baudrate limitation on serial ports (FAQ #100252)
  • Communication interface isn't reset on SW watchdog restart with option XOB0 enabled (FAQ #100243)
  • Firmware version naming of non-Saia PCD® COSinus systems (FAQ #100176)
  • Not all History entries can be found in the Online Help of PG5 (FAQ #100173)
  • Why is the instruction DSP not supported on Saia PCD® COSinus systems? (FAQ #100034)

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download