• PCD3.W3xx

  • Analogue input modules

Documentation

System Catalogue : PCD3

Extract 26-215_A0120 System Catalogue : PCD3

Chapter:
Automation Stations - PCD3

ENG18c .pdf 4.66 MB Download
FRA18c .pdf 4.67 MB Download
GER18c .pdf 4.69 MB Download
ITA18c .pdf 4.67 MB Download

PCD2/3.W3x5 + PCD2/3.W6x5

Datasheet PP26-393 PCD2/3.W3x5 + PCD2/3.W6x5

Analogue I/O-modules with electrical isolation (galvanic separation of outputs to PCD, the channels themselves are not separated against each other)

ENG09 .pdf 0.45 MB Download
FRA09 .pdf 0.45 MB Download
GER09 .pdf 0.45 MB Download
ITA09 .pdf 0.47 MB Download
SPA09 .pdf 0.45 MB Download
SWE09 .pdf 0.47 MB Download

PCD3.W300 - Analogue inputs, 0...10 V

Datasheet 31-632 PCD3.W300 - Analogue inputs, 0...10 V

Analogue input module, 8 channels, 12 bits, 0...10 V (connector type A included)

ENG03 .pdf 1.05 MB Download
FRA03 .pdf 1.06 MB Download
GER03 .pdf 1.06 MB Download
ITA03 .pdf 1.05 MB Download
SPA03 .pdf 1.06 MB Download

PCD3.W305 - Analogue inputs, 7 channels, 12 bit

Datasheet 31-633 PCD3.W305 - Analogue inputs, 7 channels, 12 bit

High-speed analogue input module for general use with galvanic isolation, 7 channels:
- 0…10 V
- 12 bit resolution

Galvanic separation of inputs to Saia PCD®, channels themselves not separated.

 

 

ENG04 .pdf 1.14 MB Download
FRA04 .pdf 1.15 MB Download
GER04 .pdf 1.14 MB Download
ITA04 .pdf 1.15 MB Download
SPA04 .pdf 1.15 MB Download

PCD3.W310 - Analogue inputs, 0...20 mA

Datasheet 31-636 PCD3.W310 - Analogue inputs, 0...20 mA

Analogue input module, 8 channels, 12 bits, 0...20 mA (connector type A included)

ENG03 .pdf 1.09 MB Download
FRA03 .pdf 1.10 MB Download
GER03 .pdf 1.10 MB Download
ITA03 .pdf 1.10 MB Download
SPA .pdf 1.11 MB Download

PCD3.W315 - Analogue inputs, 7 channels, 12 bit

Datasheet 31-634 PCD3.W315 - Analogue inputs, 7 channels, 12 bit

High-speed analogue input module for general use with galvanic isolation, 7 channels:
- 0…20 mA
- 12 bit resolution

Galvanic separation of inputs to Saia PCD®, channels themselves not separated.

ENG03 .pdf 1.18 MB Download
FRA03 .pdf 1.18 MB Download
GER03 .pdf 1.17 MB Download
ITA03 .pdf 1.18 MB Download
SPA03 .pdf 1.19 MB Download

PCD3.W325 - Analogue inputs, 7 channels, 12 bit

Datasheet 31-635 PCD3.W325 - Analogue inputs, 7 channels, 12 bit

High-speed analogue input module for general use with galvanic isolation, 7 channels:
- –10 V…+10 V,
- 12 bit resolution

Galvanic separation of inputs to Saia PCD®, channels themselves not separated.

ENG04 .pdf 1.14 MB Download
FRA04 .pdf 1.15 MB Download
GER04 .pdf 1.14 MB Download
ITA04 .pdf 1.15 MB Download
SPA04 .pdf 1.20 MB Download

PCD3.W340 - Analogue inp., 8 channels, 12 bits

Datasheet 31-637 PCD3.W340 - Analogue inp., 8 channels, 12 bits

Measurement parameter:

- 0…10V
- 0…2.5V
- 0…20 mA
- Pt/Ni1000 (default)
- Pt1000: –50…+400°C
- Ni1000: –50…+200°C

ENG06 .pdf 1.42 MB Download
FRA06 .pdf 1.42 MB Download
GER06 .pdf 1.44 MB Download
ITA06 .pdf 1.44 MB Download
SPA06 .pdf 1.38 MB Download

PCD3.W350 - Analogue inputs, Pt/Ni 100

Datasheet 31-638 PCD3.W350 - Analogue inputs, Pt/Ni 100

Analogue input module, 8 inputs (channels), resolution 12 bit, signal range Pt100 / Ni100, (the channels themselves not separated), connection with pluggable spring terminals, plug-in type A (4 405 4954 0) included

ENG03 .pdf 1.24 MB Download
FRA03 .pdf 1.25 MB Download
GER03 .pdf 1.26 MB Download
ITA03 .pdf 1.25 MB Download
SPA03 .pdf 1.20 MB Download

PCD3.W360 - Analogue inputs, PT1000

Datasheet 31-639 PCD3.W360 - Analogue inputs, PT1000

Analogue input module, 8 inputs (channels), resolution 12 bit, signal range Pt1000, (the channels themselves not separated), connection with pluggable spring terminals, plug-in type A (4 405 4954 0)) included

ENG03 .pdf 1.14 MB Download
FRA03 .pdf 1.15 MB Download
GER03 .pdf 1.16 MB Download
ITA03 .pdf 1.15 MB Download
SPA03 .pdf 1.11 MB Download

PCD3.W380 - Universal analogue inputs

Datasheet 31-640 PCD3.W380 - Universal analogue inputs

Universal analogue input module,

8 channels, 13 bits (12 bits+sign), selectable by software,
0…10 V,
±10 V,
0…20 mA,
±20 mA,
Pt/Ni 1000,
0…2500 Ohm,
0…300 kOhm (for NTC sensors)

(2 connectors type K included)

ENG04 .pdf 1.79 MB Download
FRA04 .pdf 1.79 MB Download
GER04 .pdf 1.79 MB Download
ITA04 .pdf 1.79 MB Download
SPA04 .pdf 1.79 MB Download

PCD2/3.W380

Datasheet PP26-598 PCD2/3.W380

DE05 .pdf 0.65 MB Download
EN05 .pdf 0.64 MB Download
ES03 .pdf 0.53 MB Download

PCD2/3.W380

Manual 27-632 PCD2/3.W380

DE06 .pdf 1.39 MB Download
EN06 .pdf 1.37 MB Download
FR06 .pdf 1.42 MB Download
IT01 .pdf 0.68 MB Download

PCD3 Hardware

Manual 26-789 PCD3 Hardware

ENG21 .pdf 16.34 MB Download
FRA21 .pdf 15.65 MB Download
GER21 .pdf 17.97 MB Download
ITA21 .pdf 15.28 MB Download

IO-Modules

Manual 27-600 IO-Modules

I/O modules for the series PCD1 | PCD2 and PCD3

ENG10 .pdf 18.74 MB Download
FRA10 .pdf 17.08 MB Download
GER10 .pdf 19.21 MB Download
ITA10 .pdf 18.80 MB Download

Systemcable and adapter

Manual 26-792 Systemcable and adapter

ENG07 .pdf 2.05 MB Download
FRA07 .pdf 3.47 MB Download
GER07 .pdf 3.44 MB Download
ITA07 .pdf 3.46 MB Download

Technical Reports

Requirements for the use of the PCD2/3.W380
- PCD firmware version 1.22.17 (or higher)
- Software PG5 version 2.1.300 (or higher)

Software / Tools

EPLAN Product Macros and DXF Files can be found here
For labelling the I/O the Device Configurator from PG5 2.0 can be used.

Program example for W380, linearization of analogue values

Software Program example for W380, linearization of analogue values

- PG5 program example for the use of the linearization of the analogue values.

- Excel sheet with linearization tables for sensors NTC10k, NTC20k, LM235

PG5 program example .zip 0.83 MB Download
Excel sheet with linearization tables for sensors NTC10k, NTC20k, LM235 .zip 0.02 MB Download

PCD3 / Wxxx

  • Why are the inputs and outputs of a PCD3 systems not switched on and off correctly, or switched on and off randomly, or the I/O status not detected correctly in the PLC? (FAQ #102063)
  • On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052)
  • Why do measured input values for PCD2.W3x5 / PCD3.W3x5 cards "freeze" (FAQ #102043)
  • Why do the 0 to 10 V analog outputs of the PCD3.W800 cards 'freeze' to a random value during operation and cannot be controlled by the user program? (FAQ #102028)
  • Why do the output of the PCD2/3.W6x5 not deliver stable signals? (FAQ #102014)
  • How to read the diagnostic information of a PCD3.W745 on a PCD3.T760? (FAQ #101697)
  • Why are analogue entries of the PCD3.W745 displayed incorrectly when using the memory mapping? (FAQ #101672)
  • What is the signification of the I/O words of a PCD2/3.W525 module? (FAQ #101552)
  • Why do I get wrong values when reading a PCD2/3.W340 with media mapping? (FAQ #101416)
  • What exactly is a PCD2/3.W721 and can I order it? (FAQ #101247)
  • Why do the outputs of PCD2/3.W525 not work? (FAQ #101204)
  • Replacement possibilities for PCD2.W5x0 and PCD3.W5x0 modules (FAQ #101151)
  • PCD3.W800: how to detect if an output channel is in forced state (FAQ #101063)
  • Which module to use for Pt100 / Ni100 measurements? (FAQ #101032)
  • Can PCD2/3.W3x5 module measure "overrange values"? (FAQ #100955)
  • On the Profibus-DP or Profi-S-I/O master it isn't possible to read or write registers with address > 4095 from the slave (FAQ #100927)
  • Connecting "special" temperature sensors to analogue modules. (FAQ #100926)
  • Why is the range of analogue (current-) input modules specified as 0(4)..20 mA? (FAQ #100675)
  • Analogue modules read wrong values while beeing online with PG5 (FAQ #100631)
  • How to connect two-wire current converters? (FAQ #100623)
  • Shall the terminal 16 of the PCD2/3.W745 be connected to ground? (FAQ #100604)
  • How to configure the PCD3.W800 and A810 on an RIO Module PCD3.T760? (FAQ #100570)
  • Are the modules PCD3.W800, PCD3.A810 and PCD3.A860 supported by the PCD3.T760? (FAQ #100504)
  • What is the reason for the error "underflow" of the PCDx.W745? (FAQ #100499)
  • Frozen PCD2/3.W3x5 and PCD2/3.W6x5 modules (FAQ #100475)
  • Negative values from PCD3.T760 are not interpreted correctly on the PCD (FAQ #100466)
  • Sampling time of PCD2/3.W6x5 modules (FAQ #100395)
  • How to configure a PCD3.W745 on a PCD3.T760? (FAQ #100214)
  • Why do PCD3.Wxxx input modules placed on an extension modules PCD3.Cxxx not work properly? (FAQ #100054)

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.