The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

  • PCD4.M110/M120/M140/M440

  • Central processing units (obsolete, replaced by PCD4.M170)

Documentation

PCD4 Hardware

Manual 26-734 PCD4 Hardware

DE09 Archive .pdf 3.36 MB Download
EN09 Archive .pdf 3.31 MB Download
FR09 Archive .pdf 3.35 MB Download
IT05 Archive .pdf 3.04 MB Download

Firmware PCD4.M110/M120/M140/M440 CPU 0

PDC4.Mxx0 | Hex-files of the current official version 005 (April 1995)

Firmware PDC4.Mxx0 | Hex-files of the current official version 005 (April 1995)

EN Archive .zip 0.11 MB Download

PCD4.Mxx0 | Functionality history

History Document PCD4.Mxx0 | Functionality history

EN Archive .pdf 0.03 MB Download

PCD4.Mxx0 | Description of the current version

Firmware PCD4.Mxx0 | Description of the current version

EN Archive .txt 0.02 MB Download

PCD4.Mxx0 | Versions history, modifications, features and bugs

History Document PCD4.Mxx0 | Versions history, modifications, features and bugs

EN Archive .pdf 0.04 MB Download

Firmware CPU 1 (M440 only)

PCD4.Mxx0 | Hex-files of the current official version 001 (April 1995)

Firmware PCD4.Mxx0 | Hex-files of the current official version 001 (April 1995)

EN Archive .zip 0.14 MB Download

Good to know

The PCD4 family has been discontinued and is no longer available. Please refer to FAQ 101098 for more information until when PCD4 modules are repaired.
As the SYSRD and SYSWR instructions are not supported all libraries using this instruction are not running, for instance the modem library. A CPU Mxx5 or M170 with recent firmware has to be used.

PCD4 / _Firmware

  • Why do I sporadically get communication errors when connecting a PCD/PCS in "Secure S-Bus Data Mode"? (FAQ #101180)
  • Why do I get a "68k add Error" when writing a text on the S-Web Server? (FAQ #101049)
  • Why is the message: "Failed to get data on alarm.exe" displayed on the alarming page? (FAQ #100963)
  • Error LED of PCD is lit! How to find the problem? (FAQ #100269)
  • What EPROM burner is recommended to create firmware chips for PCD's? (FAQ #100256)
  • Baudrate limitation on serial ports (FAQ #100252)
  • Communication interface isn't reset on SW watchdog restart with option XOB0 enabled (FAQ #100243)
  • Firmware version naming of non-Saia PCD® COSinus systems (FAQ #100176)
  • Not all History entries can be found in the Online Help of PG5 (FAQ #100173)

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download