Product Index   Saia PCD Supervisor   Version overview

Version overview

---------------------------------------------------------------------------------------------------------------------------

Saia PCD Supervisor 1.1 (version 4.4.92.2.1_1.4.1903.3)

This version 1.1 does include a complete installation package of the Saia PCD Supervisor
Saia PCD Supervisor version 1.1. is based on the Niagara 4.4 update 1 framework

 

It’s possible to install the version 1.1 in parallel to the version 1.0 of the Saia PCD Supervisor on the PC.

 

To install the version 1.1 in parallel to the version 1.0 you must select/create a different folder during the installation, when you are asked about the installation folder.

 

Tu use afterwards either the version 1.0 or 1.1 you have to take care which Deamon version is running.

One possibility would be to use different shortcuts like:
C:\SBC\SaiaPCDSupervisorV1\bin\plat.exe installdaemon
C:\SBC\SaiaPCDSupervisorV1_1\bin\plat.exe installdaemon

If you want to use only the latest version 1.1 on your PC, then it’s possible to uninstall the version 1.0 and afterwards install the version 1.1

 

New features/improvements

Performance improvements:

  • Speedier user interface
  • Added server side caching technology to deliver browser content faster
  • Optimized HTML5 HX Profile for quicker loading times
  • Updated internal Workbench Web Browser. This includes improvements in speed as well as enhanced stability and security

Single Sign On capability allows easy navigation between multiple Niagara connections 

  • Stations can be configured to use SAML SSO Authentication Scheme over HTTP/HTTPS

Scheduler and Alarm Console with full HTML5 support (no longer special plug-in’s needed)

  • Live alarm updates, enhanced filters, Hyperlinking, …

Language packages for German, English, French are included in V1.1.

 

BACnet Utility improvements

  • Priorities can now be defined for Set and Override

 

Bug fixes

  • GALEO-5352 - Error while importing the Data points in SBC supervisor
  • GALEO-5349 - Alarm Import is not working since Radio button of language is disabled
  • GALEO-5985 - S-Bus value overwrite after change precision at facets
  • GALEO-4615 - „SET“ cannot be used on commendable objects if there is any active priority
  • GALEO-3894 - NCCB-30270 - Present value overwrite after change precision at facets
  • GALEO-4987 - NCCB-10507 - „offNormal > toNormal transition not sent when ack rqd. To Normal unselected
  • GALEO-8640 - Set override in hon policies is not followed properly

For Niagara 4.4 U1 bug fixes refer to Tridium web site with the following link:

---------------------------------------------------------------------------------------------------------------------------

Saia PCD Supervisor Patch XXS

  • This patch include different *.jar files and must be installed manually over the version 1.0 (version 4.3_1.3.98.0)

 

Improvements/corrections
The following corrections have been done in the patch XXS patch

  • Cyber security patch from Tridium
  • Update for cyber security in SBC Offline engineering module
  • Correction of issue with *.svg graphics where the *.svg graphics where shifted for some pixels if the visualization is displayed in a standard browser. 

---------------------------------------------------------------------------------------------------------------------------

Saia PCD Supervisor 1.0 (version 4.3_1.3.98.0)

  • First official version of the Saia PCD Supervisor
  • This version does include a complete installation package of the Saia PCD Supervisor
  • It's based on the Niagara 4.3 framework

---------------------------------------------------------------------------------------------------------------------------

PLATFORM REQUIREMENTS


Saia PCD® Supervisor will run on the following operating systems:

  • Windows 10 (32-bit)
  • Windows 10 (64-bit)
  • Windows 8.1 Professional/Enterprise/Ultimate (32-bit)
  • Windows 8.1 Professional/Enterprise/Ultimate (64-bit)
  • Windows 7 Professional/Enterprise/Ultimate (32-bit)
  • Windows 7 Professional/Enterprise/Ultimate (64-bit)
  • Windows Server 2012 R2 Standard/Enterprise (SP2) (64-bit)

 

Your PC must comply with the minimum specification for the installed operating system as specified by Microsoft.

In addition to meeting the requirements for the operating system Saia PCD® Supervisor requires the following:

  • Processor : Intel® Xeon® CPU E5-2640 x64 (orbetter), compatible with dualand quad-core processors
  • Operating System : Windows 7 (if N4 supports), 10, 64-bit Windows 8.1 Enterprise, Windows Server 2012 Standard and 2012 R2 Standard
  • Memory : 4 GB minimum, 8 GB or more recommended for larger system
  • Free Hard Drive Space : 4 GB minimum, more recommended depending on archiving requirements
  • Display : Video card and monitor capable of displaying 1680 × 1050 pixel resolution or greater
  • Network Support : Ethernet adapter (10/100 MB with RJ-45 connector)
  • Connectivity : Full-time high-speed ISP connection recommended for remote site access (i.e., T1, ADSL, cable modem)

 

If enterprise-level data archiving is required (optional), one of the following compatible database applications will need to be installed:

  • MS SQL Server 2012
  • MS SQL Server 2014

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download