Services   BIM (Building Information Model)   BIM for PLCs - PCD3

  • BIM-Objects for PLCs (Programmable Language Controller) - PCD3

    The Term Building Information Modeling (BIM) describes a method of optimizing the planning, execution and management of buildings with the help of Software. All relevant building data is digitally collected, combined and networked. As a virtual building model, the building is also geometrically visualized (Computer Model). Building Information Modeling is used both in construction and construction planning (Architecture, engineering, building engineering) and in facility management.

IEC Controllers - programmable with QRONOX

BIM - PCD3.M6893 IEC-Controller

Tutorial PCD3.M6893 BIM - PCD3.M6893 IEC-Controller

Saia PCD3.M6893 - IEC Controller

The most recent cyber security level (ANSI ISA 62443 – SL3/SL4) enables the use in mission critical and IoT / Cloud applications.

Main features

- PCD3 controller without battery
- 1 × GByte RAM and 4 GByte Flash for operating system and user program
- 1 × Socket for user data micro-SD card, max. 32 GByte
- 2 × Ethernet
- 1 × RS-485
- 1 × socket for PCD7.F1xxS communication modules
- 1 × CAN galvanic separated
- 1 × USB Device port for programming and service
- 1 × USB host 2 × interrupt inputs
- 1 × watch dog relay
- extendable up to 1023 I/O

Supported PCD3 - I/O Modules:

- Connector for I/O Extension PCD3.C200
- Starting with firmware 0.0.0.281: PCD3.Ax, …Ex, …W3x5, …W6x5

PDS - xlsx Draft Download
Revit-file - .rfa - Revision: a .zip 0.30 MB Download
CREO-export - .sat .zip 0.03 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series

BIM - PCD3 processor unit: PCD3.M6880

Tutorial PCD3.M6880 BIM - PCD3 processor unit: PCD3.M6880

CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series

PCD3 Standby processor unit with 2 Ethernet TCP/IP and Co-processor for Standby operation, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net/MPI/S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.17 MB Download
Step-file - .stp .zip 0.17 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.05 MB Download
IGES-file - .iges .zip 0.08 MB Download
OCA-file - .oca .zip 0.00 MB Download
STL-file - .stl .zip 0.02 MB Download
DS - 34-008 ENG .pdf 1.39 MB Download
DS - 34-008 FRA .pdf 1.40 MB Download
DS - 34-008 GER .pdf 1.41 MB Download
DS - 34-008 ITA .pdf 1.40 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M6860

Tutorial PCD3.M6860 BIM - PCD3 processor unit: PCD3.M6860

CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series

PCD3 processor unit with 2 Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net/MPI/S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.17 MB Download
Step-file - .stp .zip 0.17 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.05 MB Download
IGES-file - .iges .zip 0.08 MB Download
STL-file - .stl .zip 0.02 MB Download
DS - 34-007 ENG .pdf 0.37 MB Download
DS - 34-007 FRA .pdf 0.37 MB Download
DS - 34-007 GER .pdf 0.37 MB Download
DS - 34-007 ITA .pdf 0.37 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M6560

Tutorial PCD3.M6560 BIM - PCD3 processor unit: PCD3.M6560

CPU base units for 4 plug-in I/O modules - Saia PCD3.M6 series

PCD3 processor unit with Profibus DP Master and Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-485 for Profi-S-Net/MPI/S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.17 MB Download
Step-file - .stp .zip 0.17 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.07 MB Download
IGES-file - .iges .zip 0.08 MB Download
STL-file - .stl .zip 0.02 MB Download
DS - 31-668 ENG .pdf 0.19 MB Download
DS - 31-668 FRA .pdf 0.19 MB Download
DS - 31-668 GER .pdf 0.19 MB Download
DS - 31-668 ITA .pdf 0.19 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series

BIM - PCD3 processor unit: PCD3.M5560

Tutorial PCD3.M5560 BIM - PCD3 processor unit: PCD3.M5560

Saia PCD3 modular programmable controllers

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupts, RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.17 MB Download
Step-file - .stp .zip 0.17 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.07 MB Download
IGES-file - .iges .zip 0.08 MB Download
STL-file - .stl .zip 0.02 MB Download
DS - 31-663 ENG .pdf 0.36 MB Download
DS - 31-663 FRA .pdf 0.37 MB Download
DS - 31-663 GER .pdf 0.37 MB Download
DS - 31-663 ITA .pdf 0.38 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M5540

Tutorial PCD3.M5540 BIM - PCD3 processor unit: PCD3.M5540

Saia PCD3 modular programmable controllers

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program, backup option with PCD7.R5xx/R610 Flash card, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.17 MB Download
Step-file - .stp .zip 0.17 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.07 MB Download
IGES-file - .iges .zip 0.08 MB Download
STL-file - .stl .zip 0.02 MB Download
DS - 31-662 ENG .pdf 0.36 MB Download
DS - 31-662 FRA .pdf 0.37 MB Download
DS - 31-662 GER .pdf 0.36 MB Download
DS - 31-662 ITA .pdf 0.37 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M5360

Tutorial PCD3.M5360 BIM - PCD3 processor unit: PCD3.M5360

CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus, data protection 1-3 years

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.17 MB Download
Step-file - .stp .zip 0.17 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.07 MB Download
IGES-file - .iges .zip 0.08 MB Download
STL-file - .stl .zip 0.02 MB Download
DS - 31-667 ENG .pdf 0.24 MB Download
DS - 31-667 FRA .pdf 0.25 MB Download
DS - 31-667 GER .pdf 0.25 MB Download
DS - 31-667 ITA .pdf 0.25 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M5340

Tutorial PCD3.M5340 BIM - PCD3 processor unit: PCD3.M5340

CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program, backup option with PCD7.R5xx/R610 Flash card, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.17 MB Download
Step-file - .stp .zip 0.16 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.07 MB Download
IGES-file - .iges .zip 0.08 MB Download
STL-file - .stl .zip 0.02 MB Download
DS - 26-474 ENG .pdf 0.25 MB Download
DS - 26-474 FRA .pdf 0.25 MB Download
DS - 26-474 GER .pdf 0.25 MB Download
DS - 26-474 ITA .pdf 0.25 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series

BIM - PCD3 processor unit: PCD3.M3360

Tutorial PCD3.M3360 BIM - PCD3 processor unit: PCD3.M3360

CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.15 MB Download
Step-file - .stp .zip 0.15 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.04 MB Download
IGES-file - .iges .zip 0.07 MB Download
STL-file - .stl .zip 0.01 MB Download
DS - 31-661 ENG .pdf 0.37 MB Download
DS - 31-661 FRA .pdf 0.37 MB Download
DS - 31-661 GER .pdf 0.37 MB Download
DS - 31-661 ITA .pdf 0.38 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M3330

Tutorial PCD3.M3330 BIM - PCD3 processor unit: PCD3.M3330

CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.15 MB Download
Step-file - .stp .zip 0.15 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.04 MB Download
IGES-file - .iges .zip 0.07 MB Download
STL-file - .stl .zip 0.01 MB Download
DS - 31-660 ENG .pdf 0.37 MB Download
DS - 31-660 FRA .pdf 0.37 MB Download
DS - 31-660 GER .pdf 0.37 MB Download
DS - 31-660 ITA .pdf 0.39 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M3230

Tutorial PCD3.M3230 BIM - PCD3 processor unit: PCD3.M3230

CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series

 

 

PDS - xlsx Archive .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Archive Download
CREO-export - .sat Draft Archive Download
Step-file - .step Archive .zip 0.14 MB Download
Step-file - .stp Archive .zip 0.14 MB Download
DXG-file - .dxf Draft Archive Download
IFC-file - .ifc Draft Archive Download
IGES-file - .iges Archive .zip 0.06 MB Download
STL-file - .stl Archive .zip 0.01 MB Download
Manual - 26-789 ENG Archive .pdf 16.08 MB Download
Manual - 26-789 FRA Archive .pdf 15.39 MB Download
Manual - 26-789 GER Archive .pdf 17.79 MB Download
Manual - 26-789 ITA Archive .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M3160

Tutorial PCD3.M3160 BIM - PCD3 processor unit: PCD3.M3160

CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.14 MB Download
Step-file - .stp .zip 0.14 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.03 MB Download
IGES-file - .iges .zip 0.06 MB Download
OCA-file - .oca .zip 0.00 MB Download
STL-file - .stl .zip 0.01 MB Download
DS - 31-666 ENG .pdf 0.36 MB Download
DS - 31-666 FRA .pdf 0.37 MB Download
DS - 31-666 GER .pdf 0.37 MB Download
DS - 31-666 ITA .pdf 0.38 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M3120

Tutorial PCD3.M3120 BIM - PCD3 processor unit: PCD3.M3120

CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series

PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 128 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.14 MB Download
Step-file - .stp .zip 0.14 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.03 MB Download
IGES-file - .iges .zip 0.06 MB Download
STL-file - .stl .zip 0.01 MB Download
DS - 26-447 ENG .pdf 0.38 MB Download
DS - 26-447 FRA .pdf 0.39 MB Download
DS - 26-447 GER .pdf 0.39 MB Download
DS - 26-447 ITA .pdf 0.39 MB Download
Manual - 26-789 ENG .pdf 16.08 MB Download
Manual - 26-789 FRA .pdf 15.39 MB Download
Manual - 26-789 GER .pdf 17.79 MB Download
Manual - 26-789 ITA .pdf 15.01 MB Download

BIM - PCD3 processor unit: PCD3.M3020

Tutorial PCD3.M3020 BIM - PCD3 processor unit: PCD3.M3020

CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series

 

 

PDS - xlsx Archive .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Archive Download
CREO-export - .sat Draft Archive Download
Step-file - .step Archive .zip 0.13 MB Download
Step-file - .stp Archive .zip 0.13 MB Download
DXG-file - .dxf Draft Archive Download
IFC-file - .ifc Archive .zip 0.03 MB Download
IGES-file - .iges Archive .zip 0.06 MB Download
STL-file - .stl Archive .zip 0.01 MB Download
Manual - 26-789 ENG Archive .pdf 16.08 MB Download
Manual - 26-789 FRA Archive .pdf 15.39 MB Download
Manual - 26-789 GER Archive .pdf 17.79 MB Download
Manual - 26-789 ITA Archive .pdf 15.01 MB Download

Extension module holders and cables for Compact Controllers PCD3.M2xxx

BIM - Extension unit for 2 I/O modules

Tutorial PCD3.C110Z09 BIM - Extension unit for 2 I/O modules

Extension module holder for 2 I/O modules for compact controllers Saia PCD3

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.07 MB Download
Step-file - .stp .zip 0.07 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.03 MB Download
IGES-file - .iges .zip 0.03 MB Download
STL-file - .stl .zip 0.01 MB Download
Manual 26-861 - ENG .pdf 3.98 MB Download
Manual 26-861 - FRA .pdf 4.00 MB Download
Manual 26-861 - GER .pdf 4.12 MB Download
Manual 26-862 - ENG .pdf 6.05 MB Download
Manual 26-862 - FRA .pdf 5.91 MB Download
Manual 26-862 - GER .pdf 5.95 MB Download

BIM - Extension unit for 4 I/O modules

Tutorial PCD3.C200Z09 BIM - Extension unit for 4 I/O modules

Extension module holder for 4 I/O modules
with terminal connectors for external 24 VDC power supply for compact controllers Saia PCD3

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.13 MB Download
Step-file - .stp .zip 0.13 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.05 MB Download
IGES-file - .iges .zip 0.06 MB Download
STL-file - .stl .zip 0.01 MB Download
Manual 26-861 - ENG .pdf 3.98 MB Download
Manual 26-861 - FRA .pdf 4.00 MB Download
Manual 26-861 - GER .pdf 4.12 MB Download
Manual 26-862 - ENG .pdf 6.05 MB Download
Manual 26-862 - FRA .pdf 5.91 MB Download
Manual 26-862 - GER .pdf 5.95 MB Download

Extension module holders and cables for PCD3.M3xxx/..M5xxx/..M6xxx

BIM - Extension unit for 4 I/O modules

Tutorial PCD3.C100 BIM - Extension unit for 4 I/O modules

Extension module holder for 4 PCD3 I/O modules

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.12 MB Download
Step-file - .stp .zip 0.12 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.05 MB Download
IGES-file - .iges .iges 0.62 MB Download
STL-file - .stl .zip 0.01 MB Download
DS 31-680 ENG .pdf 0.55 MB Download
DS 31-680 FRA .pdf 0.55 MB Download
DS 31-680 GER .pdf 0.55 MB Download
DS 31-680 ITA .pdf 0.55 MB Download
Manual 26-789 ENG .pdf 16.08 MB Download
Manual 26-789 FRA .pdf 15.39 MB Download
Manual 26-789 GER .pdf 17.79 MB Download
Manual 26-789 ENG .pdf 15.01 MB Download

BIM - Extension unit for 2 I/O modules

Tutorial PCD3.C110 BIM - Extension unit for 2 I/O modules

Extension module holder for 2 I/O modules

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.09 MB Download
Step-file - .stp .zip 0.09 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.07 MB Download
IGES-file - .iges .zip 0.05 MB Download
STL-file - .stl .zip 0.03 MB Download
Manual 26-789 - ENG .pdf 16.08 MB Download
Manual 26-789 - FRA .pdf 15.39 MB Download
Manual 26-789 - GER .pdf 17.79 MB Download
Manual 26-789 - ITA .pdf 15.01 MB Download

BIM - Extension unit for 4 I/O modules ext. pwr.

Tutorial PCD3.C200 BIM - Extension unit for 4 I/O modules ext. pwr.

Extension module holder for 4 I/O modules with terminal connectors for external 24 VDC power supply

 

 

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Revision: - Draft Download
CREO-export - .sat Draft Download
Step-file - .step .zip 0.13 MB Download
Step-file - .stp .zip 0.13 MB Download
DXG-file - .dxf Draft Download
IFC-file - .ifc .zip 0.05 MB Download
IGES-file - .iges .zip 0.06 MB Download
STL-file - .stl .zip 0.02 MB Download
DS 31-682 ENG .pdf 0.55 MB Download
DS 31-682 FRA .pdf 0.55 MB Download
DS 31-682 GER .pdf 0.55 MB Download
DS 31-682 ITA .pdf 0.55 MB Download
Manual 26-789 ENG .pdf 16.08 MB Download
Manual 26-789 FRA .pdf 15.39 MB Download
Manual 26-789 GER .pdf 17.79 MB Download
Manual 26-789 ENG .pdf 15.01 MB Download

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download