• BIM for RIOs (Remote I/Os)

    The Term Building Information Modeling (BIM) describes a method of optimizing the planning, execution and management of buildings with the help of Software. All relevant building data is digitally collected, combined and networked. As a virtual building model, the building is also geometrically visualized (Computer Model). Building Information Modeling is used both in construction and construction planning (Architecture, engineering, building engineering) and in facility management.

  • S-Serie
    S-Serie
    L-Serie & programmable
    L-Serie & programmable

Documentation

E-Line S-Serie

BIM - PCD1.A1000-A20

Tutorial E-Line - S-Serie BIM - PCD1.A1000-A20

E-Line S-Serie digital output module
Manual override operating level for all outputs
Status LED for outputs
Supply 24 VDC
- 10 digital outputs 24 VDC (12…32 VDC/0.5 A)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB service interface

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: a .zip 0.29 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.A2000-A20

Tutorial E-Line - S-Serie BIM - PCD1.A2000-A20

E-Line S-Serie digital output module
manual override operating level for all outputs
status LED for outputs
supply 24 VDC
- 6 relay normally open 230 VAC / 30 VDC, 16 A (resistive load)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: a .zip 0.29 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.B1100-A20

Tutorial E-Line - S-Serie BIM - PCD1.B1100-A20

E-Line S-Serie Digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 4 digital inputs; 24 VDC (source operation)
- 10 relay (6 normally open/ 4 changeover) 250 VAC / 30 VDC, 5 A (DC1)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.15 MB Download
Revit-file - .rfa - Version: a .zip 0.29 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.B1120-A20

Tutorial E-Line - S-Serie BIM - PCD1.B1120-A20

E-Line S-Serie Digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 16 digital inputs; 24 VDC (source operation)
- 4 relay changeover 250 VAC / 30 VDC, 5 A (DC1)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.15 MB Download
Revit-file - .rfa - Version: a .zip 0.43 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.B5000-A20

Tutorial E-Line - S-Serie BIM - PCD1.B5000-A20

E-Line S-Serie Digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 6 Digital inputs 115…230 VAC
- 3 relay normally open 230 VAC / 30 VDC, 6 A (resistive load)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: a .zip 0.43 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.B5010-A20

Tutorial E-Line - S-Serie BIM - PCD1.B5010-A20

E-Line S-Serie Digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 6 Digital inputs 24 VAC/DC
- 3 relay normally open 230 VAC / 30 VDC, 6 A (resistive load)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.15 MB Download
Revit-file - .rfa - Version: a .zip 0.43 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.E1000-A10

Tutorial E-Line - S-Serie BIM - PCD1.E1000-A10

E-Line S-Serie Digital input module
status LED for inputs
supply 24 VDC
- 12 Digital inputs 24 VDC (source operation)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB service interface

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - version: a .zip 0.43 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.G2000-A20

Tutorial E-Line - S-Serie BIM - PCD1.G2000-A20

E-Line S-Serie combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 6 universal digital/analogue inputs
    - digital inputs 24 VDC
    - analoque inputs 12 bits
      0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
      0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 2 analogue outputs 10 bits, 0…10 V
- 2 triac outputs 24 VAC/1 A or 230 VAC/1 A
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: A .zip 0.30 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.G2100-A10

Tutorial E-Line - S-Serie BIM - PCD1.G2100-A10

E-Line S-Serie combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 8 universal digital/analogue inputs
   - digital inputs 24 VDC
   - analoque inputs 12 bits
     0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
     0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.15 MB Download
Revit-file - .rfa - Version: a .zip 0.43 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.G2200-A20

Tutorial E-Line - S-Serie BIM - PCD1.G2200-A20

E-Line S-Serie combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 8 universal digital/analogue inputs
   - digital inputs 24 VDC
   - analoque inputs 12 bits
     0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
     0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 4 analogue outputs 10 bits, 0…10 V
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: a .zip 0.43 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

BIM - PCD1.W5200-A20

Tutorial E-Line - S-Serie BIM - PCD1.W5200-A20

E-Line S-Serie analogue output module
manual override operating level for all outputs
status LED for outputs
supply 24 VDC
- 8 analogue outputs 10 bits, 0…10 V
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB service interface

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: a .zip 0.43 MB Download
CREO-export - .sat .zip 0.02 MB Download
Step-file - .step .zip 0.02 MB Download
Step-file - .stp .zip 0.02 MB Download

E-Line L-Serie

BIM - PCD1.B1000-A20

Tutorial E-Line - L-Serie BIM - PCD1.B1000-A20

E-Line digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 4 digital inputs 24 VDC (source operation)
- 6 relay normally open 230 VAC / 30 VDC, 4 A (resistive load)
- 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
- 1 interface RS-485 (S-Bus and Modbus)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .zip 0.28 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

BIM - PCD1.B1010-A20

Tutorial E-Line - L-Serie BIM - PCD1.B1010-A20

E-Line digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 24 digital inputs 24 VDC (source operation)
- 6 relay normally open 230 VAC / 30 VDC, 4 A (resistive load)
- 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
- 1 interface RS-485 (S-Bus and Modbus)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .zip 0.28 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

BIM - PCD1.B1020-A20

Tutorial E-Line - L-Serie BIM - PCD1.B1020-A20

E-Line digital input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 16 digital inputs 24 VDC (source operation)
- 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
- 1 interface RS-485 (S-Bus and Modbus)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .zip 0.28 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

BIM - PCD1.G5000-A20

Tutorial E-Line - L-Serie BIM - PCD1.G5000-A20

E-Line combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 16 digital inputs 24 VDC (source operation)
- 4 relay normally open 230 VAC / 30 VDC, 4 A (resistive load)
- 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
- 8 analogue inputs 12 bits
     0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 4 analogue outputs 10 bits, 0…10 V (10 mA max.)
- 1 interface RS-485 (S-Bus and Modbus)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .zip 0.29 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

BIM - PCD1.G5010-A20

Tutorial E-Line - L-Serie BIM - PCD1.G5010-A20

E-Line combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 12 digital inputs 24 VDC (source operation)
- 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
- 12 analogue inputs 12 bits
     0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 8 analogue outputs 10 bits, 0…10 V (10 mA max.)
- 1 interface RS-485 (S-Bus and Modbus)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .zip 0.28 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

BIM - PCD1.G5020-A20

Tutorial E-Line - L-Serie BIM - PCD1.G5020-A20

E-Line combined input/output module
manual override operating level for all outputs
status LED for inputs and outputs
supply 24 VDC
- 8 digital inputs 24 VDC (source operation)
- 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
- 16 analogue inputs 12 bits
     0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 4 analogue outputs 10 bits, 0…10 V (10 mA max.)
- 1 interface RS-485 (S-Bus and Modbus)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .zip 0.29 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

E-Line Programmable modules

BIM - PCD1.G3600-C15

Tutorial E-Line programmable modules BIM - PCD1.G3600-C15

Programmable E-Line input/output module
for room automation
supply 24 VAC/VDC
- 8 digital inputs 24 VAC/VDC
- 3 relay changeover 230 VAC / 30 VDC, 6 A, max. inrush current 15 A
- 1 relay changeover 230 VAC / 30 VDC, 10 A, max. inrush current 65 A
- 4 triac outputs 24 VCA/1A or 230 VAC/1 A
- 4 analogue inputs 12 bits
     0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 4 analogue outputs 12 bits, 0…10 V (3 mA max.)
- 3 interfaces: RS-485 (S-Bus), USB & NFC (service)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .zip 0.29 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

BIM - PCD1.G3601-C15

Tutorial E-Line programmable modules BIM - PCD1.G3601-C15

Programmable E-Line input/output module for room automation with auxiliary RS-485 interface
supply 24 VAC/VDC
- 8 digital inputs 24 VAC/VDC
- 3 relay changeover 230 VAC / 30 VDC, 6 A, max. inrush current 15 A
- 1 relay changeover 230 VAC / 30 VDC, 10 A, max. inrush current 65 A
- 4 triac outputs 24 VCA/1A or 230 VAC/1 A
- 4 analogue inputs 12 bits
     0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm
- 4 analogue outputs 12 bits, 0…10 V (3 mA max.)
- 4 interfaces: RS-485 (S-Bus), auxiliary RS-485, USB & NFC (service)

PDS - xlsx .pdf 0.31 MB Download
Revit-file - .rfa - Version: - .RFA 0.32 MB Download
CREO-export - .sat .zip 0.01 MB Download
Step-file - .step .zip 0.01 MB Download
Step-file - .stp .zip 0.01 MB Download

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download