Product Category   Remote I/O   PCD3.T66x Smart Ethernet RIO

  • PCD3.T665 | PCD3.T666

  • Smart Ethernet RIOs

Documentation

System Catalogue : PCD3

Extract PP26-215_A0120 System Catalogue : PCD3

Chapter:
Automation Stations - PCD3

ENG16 .pdf 7.08 MB Download
FRA16 .pdf 7.10 MB Download
GER16 .pdf 7.10 MB Download
ITA16 .pdf 7.10 MB Download

Smart-RIO PCD3.T665/T666

Manual 26-892 Smart-RIO PCD3.T665/T666

  

ENG06 .pdf 6.83 MB Download
FRA06 .pdf 6.88 MB Download
GER06 .pdf 6.83 MB Download
ITA06 .pdf 6.87 MB Download

PCD3 Hardware

Manual 26-789 PCD3 Hardware

ENG19 .pdf 16.11 MB Download
FRA19 .pdf 15.43 MB Download
GER19 .pdf 17.69 MB Download
ITA19 .pdf 14.98 MB Download

IO-Modules

Manual 27-600 IO-Modules

I/O modules for the series PCD1 | PCD2 and PCD3

ENG08 .pdf 13.08 MB Download
FRA08 .pdf 16.45 MB Download
GER08 .pdf 15.48 MB Download
ITA08 .pdf 12.56 MB Download

TCP/IP - Ethernet for the Saia PCD® Serie

Manual 26-776 TCP/IP - Ethernet for the Saia PCD® Serie

ENG12 .pdf 20.76 MB Download
FRA12 .pdf 20.54 MB Download
GER12 .pdf 10.16 MB Download
IT03 Archive .pdf 4.43 MB Download

TCP/IP-Enhancements

Manual 26-867 TCP/IP-Enhancements

DE04 .pdf 3.61 MB Download
EN04 .pdf 3.73 MB Download
FR04 .pdf 3.63 MB Download

Firmware used in production

The actual COSinus FW 1.22.xx is available from the COSinus firmware page.

Software / Tools

For the power calculation of the I/O modules the Device Configurator from PG5 2.0. SP2 is to be used. PG5 2.0 Device Configurator does also feature a label creator for the I/Os on the RIO.

Good to know

FW 1.20.36 or newer is needed to feature the integration of L&S NI1000 temperature sensors on different W-Modules. This Firmware also supports the use of 16k Registers / Flags. Therefore you also need the PG5 2.1.100.100.

FW 1.16.52 or newer is needed to use the PCD3.F27x (except PCD3.F270) module on the PCD3.T766.
There is an example from the Smart Ethernet RIOs available in the Getting Started section.

PG5 2.0.200 does not correctly map the "ManagerNotPresent" diagnostic flag, see FAQ 101652.

The RIO firmware 1.16.42 does not update the diagnostic flags if started without manager, see FAQ 101653. Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640.

Minimal version of PG5 for configuring a PCD3.T665|T666 is PG5 2.0 SP2 (PG5 2.0.200).

When replacing a PCD3.T660 by a PCD3.T665 the user program needs to be adapted accordingly.

I/O modules:
The I/O modules are delivered per default with a spring clamp terminal block.
Screw terminal blocks have to be ordered separately.

Communication / Ether-S-I/O

  • It's possible that the same master PCD is able to handle PCD3.T665/T666 and PCD3.T660? (FAQ #101842)
  • Why can't I copy an Ethernet RIO within the Saia PG5® RIO Network Configurator? (FAQ #101678)
  • Why can't I detect that the RIO manager is missing during the start of the RIO? (FAQ #101653)
  • Why is the diagnostic flag "ManagerNotPresent" on the RIO not set? (FAQ #101652)

PG5 2.0 / Library Manager

  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #102018)

PCD3 / T665 | T666

  • Why is the diagnostic flag of the PCD3.T665 / T666 partially not automatically reset on the Ethernet Smart-RIO manager after Ethernet network interruption? (FAQ #101995)
  • Why appears the following S-RIO internal error message? (FAQ #101940)
  • Can I use DALI on the PCD3.T666? (FAQ #101902)
  • On PG5 2.1 the 'fatal error 2004' is shown after building a project where a smart RIO PCD3.T665/T666 is used. (FAQ #101871)
  • The data exchange to smart RIO does not work with certain FW version! (FAQ #101860)
  • It's possible that the same master PCD is able to handle PCD3.T665/T666 and PCD3.T660? (FAQ #101842)
  • What are the differences between firmware 1.16.69 and COSinus FW 1.22.61? (FAQ #101820)
  • SWeb Alarming is not supported on Smart-RIO PCD3.T665 / PCD3.T666 (FAQ #101803)
  • Why the exchange of ‘data transfer array’ between the PCD3.T66x smart RIO’s and the smart automation manager does no more work after installing the patch 1 of PG5 2.0.220? (FAQ #101785)
  • What is the signification of the history entry "ESIO CFG FAIL nn"? (FAQ #101778)
  • Can I "stop" the programm execution of a Smart Ethernet RIO (PCD3.T665 or PCD3.T666)? (FAQ #101768)
  • Diagnostic flag from SMART RIO is high for a short time after a program download (FAQ #101752)
  • Why can't I detect that the RIO manager is missing during the start of the RIO? (FAQ #101653)
  • Why is the diagnostic flag "ManagerNotPresent" on the RIO not set? (FAQ #101652)
  • Why does the data exchange to the RIO not work after the program has been restored? (FAQ #101640)
  • What are the differences between firmware 1.14.23 and 1.16.69? (FAQ #101624)
  • Which special modules can I plug on the PCD3.T666? (FAQ #101603)